Technical Data
Acoustics
R2R
ROOM TO ROOM NOISENoise to and from adjacent rooms should be considered. |
Ceiling
ACC
ACOUSTIC CEILING TYPEAcoustic absorptive ceiling (A). Refer to DG / CEILING |
Communications
CO
COMMUNICATIONS/TELEPHONE POINTSCommunications/Telephone point requirements and considerations apply. Refer to DG / COMMUNICATIONS AUDIO VISUAL REQUIREMENTSAudio visual and intercommunication facilites may be required. Refer to DG / COMMUNICATIONS WIRELESS ACCESS POINTS |
Doors
DT
DOOR TYPEThe reception opening should have a security roller shutter on the Clerical/Printing side. An acoustic operable wall to divide room into two may be used. Two doors connecting to circulation space are recommended. Refer to DG / DOORS ACOUSTIC RATED DOORSAcoustic rated doors are required. |
Drainage
SD
SANITARY DRAINAGE FIXTURES1 drainage outlet. Refer to DG / DRAINAGE |
|
Fire Protection
FD
FIRE DETECTION/ALARMSFire detection/alarms to comply with NCC. Refer to DG / THERMAL/SMOKE DETECTORS PORTABLE FIRE EXTINGUISHER/ BLANKETPortable fire extinguisher required where electrical equipment located in space to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT FIRE HOSE REELFire Hose Reels as required to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT |
Floor
FF
FLOOR FINISHCarpet finish. Refer to DG / FLOOR |
|
Heating
H
HEATINGProvide heating where regionally appropriate. Refer to DG / HEATING |
Illumination
LUX
LUX LEVEL320 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed differently (key to differ). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff. Refer to SG / DOOR HARDWARE / KEYING |
Light
DL
DAYLIGHTDaylight is recommended for this space. |
Planning
m^2
AREAType 3 - 53 m2 for Core fourteen. Type 4 - 60 m2 for Core twenty one. Refer to DG / AREA PLANNING - OTHERAdjacent to Administration (PS601) entry with observation and reception opening/window. Type 3 and Type 4 can also be adjacent to Sick Bay (PS601.51). Refer to DG / AREA PROPORTIONMinimum depths apply to Type 1 (3m) and Type 2 (3.3m). Proportions of space approximately 1:1.5. Refer to DG / AREA |
Power
CM
CABLE MANAGEMENTCable management to be considered. Refer to DG / POWER GENERAL POWER OUTLETSGeneral power outlets required. Refer to DG / POWER POWER - OTHEROther power considerations may apply. Refer to DG / POWER |
Security
C
SECURITY LEVEL CCategory C - Medium Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS CCTV CAMERASCCTV cameras are required in this space. Refer to DG / SPECIAL ELECTRICAL SYSTEMS |
Signs
DSF
DOOR SIGNAGEDoor signage required. Suggested text "Office". Refer to DG / DOOR SIGNS SIGNS GENERALNotice "ENSURE VENTILATION SYSTEM IN OPERATION", in a conspicuous position. Refer to DG / SIGNS |
Ventilation
EXH
GENERAL EXHAUSTGeneral Exhausted required. Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHERSplashback 450mm high to basin. Refer to SG / LINING |
Water
N/A
|
Windows
Y
WINDOWS - YWindows are required for this space. |