GUIDE NOTE: Refer to Design Guide sections DG/ HYDRAULICS GENERALLY, DG / DRAINAGE (& TRADE WASTE).
As per current NATSPEC 0821 Stormwater - Buildings
As per current NATSPEC 0821 Stormwater – Buildings
GUIDE NOTE: Complete the list of nominating items or alternatively indicate items for which samples are required in accordance with NATSPEC
As per current NATSPEC 0821 Stormwater - BUildings except as follows:
Location - Concealed and/or encased downpipes to be avoided in all DoE facilities unless a prior approval is obtained.
Downpipe connections:
Turn up the drain branch pipeline with a suitable bend in direct line with the downpipe. Leave space between pipe collar and bottom of downpipe as shown on drawings.Downpipe to ensure effectiveness of water flow diversion into the drain
Protection, pipe collar: Encase in a proprietary precast concrete surround with a dish drain incorporated as shown on drawings.
Dish diameter: 300mm.
Minimum dish depth: 50mm around grate.
Grate installation: Prevent movement from unauthorised personnel.