GUIDE NOTE: Refer to Design Guide sections DG/ FABRIC, DG/ MATERIALS AND FINISHES, DG/ CEILING.
As per current NATSPEC except as follows:
General
Requirement: Comply with BCA Specification C1.10a which sets out requirements in relation to the fire hazard properties of wall and ceiling linings.
Wall and ceiling linings must comply with BCA Specification C1.10a Table 3, Wall and Ceiling Linings Materials (Material Groups Permitted).
As per current NATSPEC.
As per current NATSPEC except as follows:
Register / ceiling grille for roof ventilator
Refer to SG / ROOFING
Minimum size: The minimum clear area of the register / grille must be equal to the diameter of the rotary ventilator throat.
As per current NATSPEC except as follows:
Performance Criteria
Suspended ceiling system selections should be based on the following performance criteria:
GUIDE NOTE: Refer to the Educational Facilities Standards and Guidelines for areas which require Acoustic Ceilings.
Select an acoutic ceiling system from the following alternatives. Specify the appropriate acoustic blanket to suit the requirements of the room.
Corrugated and perforated metal ceiling lining – standard profile
Type: Proprietary perforated and roll-formed corrugated steel zincalume sheet and purpose made accessories forming part of a system to AS 1562.1.
Material: Pre-painted and organic film/laminate products: To AS 2728, Category 3 or 4 as appropriate to all ceiling sheets/panels and metal trims.
Thickness: 0.42 mm (minimum) B.M.T. (Base Metal Thickness)
Corrugation depth: 16 mm (minimum)
Suspension system:
Acoustic blanket: Polyester fibre black lined acoustic blanket manufactured from thermally bonded polyester.
Corrugated and perforated metal ceiling lining – mini profile
Type: Proprietary perforated and roll-formed corrugated steel zincalume sheet and purpose made accessories forming part of a system to AS 1562.1.
Material: Pre-painted and organic film/laminate products: To AS 2728, Category 3 or 4 as appropriate to all ceiling sheets/panels and metal trims.
Thickness: 0.42 mm (minimum) B.M.T. (Base Metal Thickness).
Corrugation depth: 6 mm (minimum).
Suspension system:
Acoustic blanket: Polyester fibre black lined acoustic blanket manufactured from thermally bonded polyester.
Type: Perforated linear metal ceiling - school series, consisting of panels made from colour-coated 0.4mm thick galvanised steel, 84mm wide x 15mm deep with square sides.
Finish: Polar White, 5% gloss.
Suspension system: Panel carriers made from colour-coated 0.5mm thick steel, matt black, 62mm wide x 29mm deep, with prongs to hold the panels in a module of 50mm.
Installation: In accordance with the manufacturer’s fixing instructions.
Acoustic blanket: Polyester fibre black lined acoustic blanket manufactured from thermally bonded polyester.
Perforated plasterboard ceiling
Type: 13mm thick perforated plasterboard sheet.
Plasterboard: To AS/NZS 2588
Suspension system:
Acoustic blanket: Polyester fibre black lined acoustic blanket manufactured from thermally bonded polyester.
Type: Fire resistant proprietary acoustic impervious ceiling panels with a high density, resin bonded insulation with primed edges and a white micro-porous painted surface specially designed for use in hygienic locations. The surface must be capable of being cleaned on a regular basis with a damp cloth.
Size (nominal): 1200 x 600 x 20mm thick or 600 x 600 x 20mm thick.
Suspension system: A proprietary corrosion resistant grid suspension system in accordance with the manufacturers printed instructions. Provide accessories and trim to complete installation.
Installation:
NRC: >85
Weight including grid system (nominal): 3 – 4kg/m2
Colour: White