GUIDE NOTE: Refer to Design Guide sections DG/ HYDRAULICS GENERALLY , DG DRAINAGE (& TRADE WASTE) .
As per current NATSPEC 0815 Drinking Water Dispensers except as follows :
In accordance with the NSW Government Resource Efficiency Policy, all fixtures and fittings must be at least the average WELS star rating by product type. Where WELS rating is not available, use the alternative WaterMark rating scheme.
All new water-using appliances must be at least 0.5 stars above the average Water Efficiency Labelling and Standards (WELS) star rating by product type, except toilets and urinals, which must be purchased at the average WELS star rating.
Appliances and equipment purchased in the following categories with star ratings under the WELS
scheme will be at least:
Consult with the local health authority and the School Principal for specific requirements for Infectious disease control for drinking water outlets and water bottle filling outlets at the school.
As per current NATSPEC 0815.2 Products.
As per current NATSPEC 0815.3 Execution
As per current NATSPEC 0815.4 Selections except as follows:
GUIDE NOTE: Delete subclause "4.1 Water Dispenser Systems" nominated in NATSPEC Building Template/ Worksection and replace with the following text:
Property |
A |
B |
C |
Manufacturer |
|
|
|
Dispenser system |
|
|
|
Capacity/flow rate |
|
|
|
Water delivered |
|
|
|
Warranty |
|
|
|
Options |
|
|
|
Finish |
|
|
|
Font |
|
|
|
Air cooled model |
|
|
|
Mixer tap |
|
|
|
Sink mixer disabled lever |
|
|
|
Dispenser style |
|
|
|
Filter |
|
|
|
Tundish/outlet |
|
|
|
Mounting |
|
|
|
Property |
Equal to A |
Location |
General |
|
Single Unit Drinking Fountains not to be used in schools See was / drinking trough |
Property |
Equal to A |
Location |
General |
|
Provide Water Bottle Fillers at each Drinking Water Dispenser Station |
Property |
Equal to A |
||
Location |
Boys + Girls Toilets, Outdoor learning areas, Drinking facilities general, HS showers + change |
||
Brand |
Marko Stainless Steel Products |
||
Catalogue number or model |
PW Wallsend Pattern with support assembly, ss splashback Refer to EFSG / SG / SG DRAWING SG 603/3 |
||
Material |
Stainless steel Grade 304 No4 linish 0.9 mm thick |
||
Outlet |
50mm, SS grate with sufficient fall to effectively drain water to the grate. |
||
Corners + Edging |
Radius rounding finish to all corners, Return folds to remove all exposed leading edges. Sharp edges are not accepted. |
||
Identification |
Manufacturers name to be permanently embossed in a clear visible location on the trough |
||
Plumbing |
Chrome plated copper or SS. MANDATORY : PVC piping or PVC waste pipes or traps or flexible piping are not to be used. |
||
Rim Height to ground or FFL |
|
Wash trough |
Drinking Trough |
|
Pre School |
550 mm |
550 mm |
|
Primary |
650 mm |
700 mm |
|
Secondary |
700 mm |
900 mm |
Bottle Filler Outlet |
Provide for minimum 1 water bottle filling outlet in addition to bubbler outlets |
||
Trough Guard |
Refer to SG / METALWORK / DRINKING/WASH TROUGH GUARD Drinking Trough Guards to be installed on all external Drinking Troughs |
||
Splash Back |
Height 300mm. Fixed securely to wall |
||
Support Assembly |
40mm x 6mm MS assembly with pre-drilled fixing holes. Fully welded. Hot dip Galvanised after fabrication. Fix securely to wall through pre drilled holes with noncorrosive fasteners and 10mm dia min masonry anchors. Refer to SG / METALWORK / BRACKET FOR DRINKING WATER/WASH TROUGH |
Property |
Equal to A |
|
GUIDE NOTE: Refer to Educational Facilities Standards and Guidelines for appropriate location requirements. |
Location |
Only to be provided west of 33 degree Isotherm |
Type |
Mains connected storage system water cooler with tin plated reservoir fitted with drain to facilitate periodic cleaning. |
Reservoir Capacity |
123 litre |
Refrigerant |
Non-toxic and inflammable |
Temperature Control |
Thermostat, factory pre-set |
Compressor |
½ hp capacity, 1120 watts. Hermetically sealed for silent running. |
Condenser |
Copper tube and aluminium fin |
Rating Conditions – Performance |
Outlet water 10 degree C (based on inlet temperature of 27 degree C) |
Installation |
In accordance with manufacturers instructions |
Bottle Filler Outlet |
Provide for minimum 1 water bottle filling outlet in addition to bubbler outlets |
Number of Units |
GUIDE NOTE: Refer to Educational Facilities Standards and Guidelines for determining number of chilled drinking water units. NOTE: The above nominated unit is capable of supplying up to 4 outlets during peak periods. |