Technical Data
Acoustics
N/A
|
Ceiling
OTH
CEILING - OTHERWater Resistant Ceiling ACOUSTIC CEILING TYPEStandard ceiling Refer to DG / CEILING |
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEDesigned to provide user privacy Minimum 700 mmclear for Ambulant accessible WC Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURES3 Drainage outlets Refer to DG / DRAINAGE |
Fire Protection
FD
FIRE DETECTION/ALARMSFire detection/alarms to comply with NCC. Refer to DG / THERMAL/SMOKE DETECTORS PORTABLE FIRE EXTINGUISHER/ BLANKETPortable fire extinguisher required. Comply with NCC. |
Floor
FF
FLOOR FINISHCT - Ceramic tiles. Refer to DG / FLOOR FLOOR WASTEFloor waste(s) are to be included with falls in floor. Refer to DG / DRAINAGE (& TRADE WASTE) FLOOR OTHERWater Resistant Floor. Grade floor to floow waste for drainage. Refer to DG / FLOOR |
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed Alike Toilets (T). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff (AF). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Planning
m^2
AREA5 m2 Refer to DG / AREA PLANNING - OTHERDesigned to provide occupant privacy To be designed to meet regulation requirements At least one Disabled WC is to be provided in each group of toilets. Refer to DG / AREA PROPORTIONGenerally layout to suite fittings. At least one cubicle to be designed as an Ambulatnt Accessible Wc to meet regulations. Refer to DG / AREA |
Power
N/A
|
Security
A
SECURITY LEVEL ACategory A - Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"TOILET" Refer to DG / DOOR SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION EXHAUSTMechnical exhaust. Refer to DG / VENTILATION |
Wall
OTH
WALLS - OTHERWater resistant walls 450mm high splashback above basin. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
HW
HOT WATERHot water required to 1 x basin. Refer to DG / WATER COLD WATERCW Required to 1 x basin, 1 x WC. Refer to DG / WATER |
Windows
OTH
WINDOWS - OTHERIf windows are included obscure glazing and ensure visual privacy when windows open. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |