Technical Data
Acoustics
N/A
|
Ceiling
RES
RESISTANCEWater Resistant Ceiling. Refer to DG / CEILING CEILING - OTHERCeilings to be easy clean. Refer to 'Suggested Fixtures' list and SG / METALWORK / CEILING HOOK |
Communications
OTH
COMMUNICATIONS- OTHERInclude Alarm Call System. Refer to DG / COMMUNICATIONS |
Cooling
N/A
|
Doors
DT
DOOR TYPEMinimum width as required by legislation Solid Core Door without closer preferred. Curtain may be used internally for visual privacy Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURESType 2 - 6 drainage outlets Type 3 - 6 drainage outlets Type 4 - 8 drainage outlets Refer to DG / DRAINAGE |
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCT - Ceramic Tiles. Refer to DG / FLOOR FLOOR WASTEFloor waste(s) are to be included with falls in floor. Refer to DG / DRAINAGE (& TRADE WASTE) FLOOR - OTHERCoved skirting tiles at wall Falls to floor waste. Tiles are to have flush joints and not to have a bevelled edge. Avoid abrupt changes in level. Refer to DG / FLOOR |
|
Heating
OTH
HEATING - OTHERInclude local heating to shower area refer to Design Guide. Refer to DG / HOT WATER HEATERS HEATINGProvide heating where regionally appropriate. Refer to DG / HEATING |
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed Alike Toilets (T) Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff (AF). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Planning
m^2
AREAType 2 - 20m2 Type 3 - 21m2 Type 4 - 30m2 Refer to DG / AREA PLANNING - OTHERWhere multiple Access WC's provided ensure equal numbers of each hand. Ensure Visual privacy of toilet area. Refer to DG / AREA PROPORTIONSdesigned to meet regulatory requirements. At least 1 Access WC cubicle required per group of toilets. Refer to DG / AREA |
Power
GPO
GENERAL POWER OUTLETSType 2 - 2 double socket outlets Type 3 - 1 double socket outlet Type 4 - 1 double socket outlet Refer to DG / POWER |
Security
A
SECURITY LEVEL ACategory A - Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS SECURITY OTHERAlarm Call system with Alarm to Office area. Refer to DG / SPECIAL ELECTRICAL SYSTEMS |
Signs
DSF
DOOR SIGNAGEBrail and tactile signage "TOILET/SHOWER" Refer to DG / DOOR SIGNS SIGNS GENERALBraille and Tactile signage as required by access regulations Notice "Assistance required in Access Shower/Toilet when buzzer sounds", in nearest permanently occupied space. Refer to DG / SIGNS |
Ventilation
EXH
GENERAL EXHAUSTGeneral Exhaust required. Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHERBrickwork walls with ceramic tiles to minimum 1.5m height and 2.1m in shower area. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
HW
TEMPERED WATERTypes 2 & 3 - required to 2 x basins, 1 x shower. Type 4 - required to 3 x basins, 1 x shower. Refer to DG / WATER COLD WATERTypes 2 & 3 - CW required to 2 x basins, 2 x WC's, 1 x shower. Type 4 - CW requried to 3 x basins, 3 x WC's, 1 x shower. Refer to DG / WATER |
Windows
OTH
WINDOWS - OTHERIf windows are included obscure glazing and ensure visual privacy when windows open Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |