Technical Data
Acoustics
R2R
ROOM TO ROOM NOISENoise to and from adjacent rooms should be considered. |
Ceiling
ACC
ACOUSTIC CEILING TYPEAcoustic absorptive ceiling (A). Refer to DG / CEILING |
Communications
N/A
|
Cooling
FAN
FANFor Type 2 only, a fan is required. |
Doors
DT
DOOR TYPEMinimum 1m clear width Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURES2 drainage outlets Refer to DG / DRAINAGE |
Fire Protection
FHR
FIRE HOSE REELFire Hose Reels as required to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT |
Floor
FF
FLOOR FINISHCeramic tiled floor finish (tile joints be flush) Refer to DG / FLOOR FLOOR WASTEFloor waste(s) are to be included with falls in floor. Refer to DG / DRAINAGE (& TRADE WASTE) FLOOR - OTHERWaterproofed floor with coved skirting; floor waste with falls in floor. Refer to DG / FLOOR |
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL320 lux Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed alike - Toilets Refer to SG455 / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff Refer to SG455 / DOOR HARDWARE / KEYING |
Light
N/A
|
Planning
|
|
Security
B
SECURITY LEVEL BCategory B - Moderately Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGELAUNDRY Door Sign. When Adjacent to Access WC Shower include "ACCESSIBLE UNISEX TOILET AND SHOWER " Braille & Tactile Door Sign Refer to DG / SIGNS SIGNS GENERALSign with red writing and symbol “Warning – this fixture may deliver hot water which will scald.” - adjacent to the sink Refer to DG / SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION GENERAL EXHAUSTFor Type 2 include a toilet exhaust Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHERWater and impact resistant to 1500mm high; brickwork is preferable for easy cleaning. An easy clean water resistant splashback to laundry tub is also recommended. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
HW
HOT WATERRequired to 1 x laundry tub & washing machine Refer to DG / WATER COLD WATERRequired to 1 x laundry tub & washing machine Refer to DG / WATER |
Windows
VP
VISUAL PRIVACYVisual privacy is required from other spaces. |