Technical Data
Acoustics
N/A
|
Ceiling
|
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEMinimum 1500mm clear opening width for equipment. Fire rated if part of Communal Hall Building. Refer to DG / DOORS FIRE-RATED DOORSFire-rated doors are required. |
Drainage
N/A
|
Fire Protection
FHR
FIRE HOSE REELFire Hose Reels as required to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT |
Floor
FF
FLOOR FINISHSteel troweled concrete. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed differently (key to differ). Refer to SG455 / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Storage Spaces. Refer to SG455 / DOOR HARDWARE / KEYING |
Light
N/A
|
Planning
m^2
AREAType 1 - 8 m2 for Core seven Type 2 - 13 m2 for Core fourteen Type 3 - 17 m2 for Core twenty one Refer to DG / AREA PLANNING - OTHERIf part of Communal Hall unit, fire separated from other areas (FRL 60/60/60). Refer to DG / AREA PROPORTIONIf part of a Communal Hall unit, to be designed as an entertainment venue store. Refer to DG / AREA |
Power
GPO
GENERAL POWER OUTLETS1 double socket outlet. Refer to DG / POWER |
Security
D
SECURITY LEVEL DCategory D - Moderately High Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGEDoor signage required. Suggested text "Sports Store". Refer to DG / DOOR SIGNS |
Ventilation
NV
NATURAL VENTILATION |
Wall
FR
FIRE RATED WALLWALL - OTHERFire rated walls to storeroom (--/60/60) if part of communal hall (Entertainment Venue). Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
N/A
|
Windows
N
WINDOWS - NWindows are not required for this space. VISUAL PRIVACYVisual privacy is required from other spaces. |