Technical Data
Acoustics
N/A
|
Communications
CO
COMMUNICATIONS/TELEPHONE POINTSCommunications/Telephone point requirements and considerations apply. Refer to DG / COMMUNICATIONS |
|
Cooling
N/A
|
Doors
DT
DOOR TYPEDoor to Home Base. Refer to DG / DOORS |
Drainage
N/A
|
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCarpet to match Home Base or industrial sheet flooring. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed differently (key to differ). Refer to SG455 / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Storage Spaces. Refer to SG455 / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
GPO
GENERAL POWER OUTLETS1 double socket outlet. Refer to DG / POWER |
|
Security
C
SECURITY LEVEL CCategory C - Medium Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"Store". |
Ventilation
EXH
GENERAL EXHAUSTProvide general exhaust if communications rack is in room. Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHERAllow for medium impact resistance. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
N/A
|
Windows
N
WINDOWS - NWindows are not required for this space. |