Technical Data
Acoustics
N/A
|
Ceiling
ACC
ACOUSTIC CEILING TYPEStandard ceiling Refer to DG / CEILING |
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEDoor can open outwards for ease of access Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURES2 Drainage outlets Refer to DG / DRAINAGE |
Fire Protection
FD
FIRE DETECTION/ALARMSFire detection/alarms to comply with NCC. Refer to DG / THERMAL/SMOKE DETECTORS PORTABLE FIRE EXTINGUISHER/ BLANKETPortable fire extinguisher/fire blanket - to comply with NCC. |
Floor
FF
FLOOR FINISHISF - Industrial sheet flooring. Refer to DG / FLOOR FLOOR WASTEFloor waste(s) are to be included with falls in floor. Refer to DG / DRAINAGE (& TRADE WASTE) FLOOR - OTHERthreshold to be flush finished to enable wheeled equipment etc. Grade floor to floor waste where provided. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING
|
Keying
KY
KEYING GENERALKeyed to Differ (KD). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Maintenance and Cleaning Facilities (MC). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
N/A
|
|
Security
B
SECURITY LEVEL BCategory B - Moderately Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"CLEANER" Refer to DG / DOOR SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION EXHAUSTMechnical exhaust. Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHER450mm high Stainless Steel Splashback to bucket sink Refer to SG / LINING |
Water
CW
COLD WATERCW Required to 1 x bucket sink. Refer to DG / WATER |
Windows
N
WINDOWS - NWindows are not required for this space. WINDOWS - OTHERIf windows are included obscure glazing and security grills are required. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |