Technical Data
Acoustics
N/A
|
Ceiling
OTH
CEILING OTHERWater Resistant and easy clean Ceiling ACOUSTIC CEILING TYPENRC: 0.6 - 0.8 Absorptive Ceiling Refer to DG / CEILING |
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEType 3 - Minimum 1m clear width (for equipment) Type 4 - Minimum 0.8m clear width. Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURES2 Drainage outlets. Refer to DG / DRAINAGE |
Fire Protection
FD
FIRE DETECTION/ALARMSFire detection/alarms to comply with NCC. Refer to DG / THERMAL/SMOKE DETECTORS |
Floor
FF
FLOOR FINISHCT- Ceramic tiles. Refer to DG / FLOOR FLOOR WASTEFloor waste(s) are to be included with falls in floor. Refer to DG / DRAINAGE (& TRADE WASTE) FLOOR - OTHERCoved skirting tiles at wall Falls to floor waste. Tiles are to have flush joints and not to have a bevelled edge. Avoid abrupt changes in level. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
|
Keying
KY
KEYING GENERALKeyed Alike Toilets (T). Refer to SG455 / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff (AF). Refer to SG455 / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
CM
CABLE MANAGEMENTCable management to be considered. Refer to DG / POWER GENERAL POWER OUTLETS2 double socket outlets. Refer to DG / POWER |
|
Security
B
SECURITY LEVEL BCategory B - Moderately Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"LAUNDRY". Refer to DG / DOOR SIGNS SIGNS GENERALBraille and Tactile signage as required by access regulations when using laundry to access toilets. Refer to DG / SIGNS |
Ventilation
|
Wall
OTH
WALL - OTHEReasy clean water resistant walls Splashback to Laundry Tub. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
HW
HOT WATERHW Required to 1 x laundry tub, 1 x washing machine. Refer to DG / WATER COLD WATERCW Required to 1 x laundry tub, 1 x washing machine. Refer to DG / WATER |
Windows
OTH
WINDOWS - OTHERIf windows are included obscure glazing and ensure visual privacy when windows open Visual privacy in Laundry when en-suite to Shower/Toilet/Change Area, obscure glazing. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |