Technical Data
Acoustics
N/A
|
Ceiling
ACC
ACOUSTIC CEILING TYPEStandard ceiling Refer to DG / CEILING |
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEMinimum threshold for trolley access. Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURES2 Drainage outlets Refer to DG / DRAINAGE |
Fire Protection
FD
FIRE DETECTION/ALARMSFire detection/alarms to comply with NCC. Refer to DG / THERMAL/SMOKE DETECTORS PORTABLE FIRE EXTINGUISHER/ BLANKETPortable fire extinguisher required. Comply with NCC. |
Floor
FF
FLOOR FINISHCC - Steel Trowel Concrete finish. Refer to DG / FLOOR FLOOR - OTHERThreshold to be flush finished to enable wheeled equipment. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed to Differ (KD). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed- Maintenance and Cleaning Facilities (MC). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
CM
CABLE MANAGEMENTCable management to be considered. Refer to DG / POWER GENERAL POWER OUTLETS1 double socket outlet. Refer to DG / POWER |
|
Security
C
SECURITY LEVEL CCategory C - Medium Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"STORE" Refer to DG / DOOR SIGNS WARNING SIGNHazardous Materials sign "FLAMMABLE LIQUID" - class 3, on the exterior of door. Refer to DG / SIGNS |
Ventilation
N/A
|
Wall
OTH
WALL - OTHER450mm high stainless steel splashback to bucket sink. Refer to SG / LINING |
Water
CW
COLD WATERCW Required to 1 x bucket sink. Refer to DG / WATER |
Windows
N
WINDOWS - NWindows are not required for this space. WINDOWS - OTHERWhen windows are provided include obscure glazing and security grilles. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |