Technical Data
Acoustics
NL
NOISE LEVELSNoise levels within this space should be considered. Refer to DG / ACOUSTICS / INTERNAL NOISE LEVELS ROOM TO ROOM NOISENoise to and from adjacent rooms should be considered. |
Ceiling
ACC
ACOUSTIC CEILING TYPEStandard ceiling Refer to DG / CEILING |
Communications
AV
AUDIO VISUAL REQUIREMENTSAudio visual monitoring (CCTV) from Clerical may be required. Refer to DG / COMMUNICATIONS WIRELESS ACCESS POINTS |
Doors
N/A
|
Drainage
SD
SANITARY DRAINAGE FIXTURES1 Drainage outlet Refer to DG / DRAINAGE |
|
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHSV - Sheet Vinyl (not foam backed). Refer to DG / FLOOR |
|
Heating
H
HEATINGProvide heating where regionally appropriate. Refer to DG / HEATING |
Illumination
LUX
LUX LEVEL240 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed to differ (KD). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff (AF). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
CM
CABLE MANAGEMENTCable management to be considered. Refer to DG / POWER GENERAL POWER OUTLETS1 double socket outlet. Refer to DG / POWER |
|
Security
A
SECURITY LEVEL ACategory A - Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS CCTV CAMERASCCTV cameras are required in this space. Refer to DG / SPECIAL ELECTRICAL SYSTEMS SECURITY - OTHERInclude Alarm Call System. |
Signs
DSF
DOOR SIGNAGE"SICK BAY" Refer to DG / DOOR SIGNS SIGNS GENERALWhen CCTV Camera installed: Notice "THIS AREA IS UNDER VIDEO SURVEILLANCE", in a conspicuous position. Refer to DG / SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION |
Wall
OTH
WALL - OTHER450mm high water resistant splashback to sink and bench. Refer to SG / LINING |
Water
HW
TEMPERED WATERTempered water required to 1 x sink. Refer to DG / WATER COLD WATERCW Required to 1 x sink. Refer to DG / WATER |
Windows
OTH