Technical Data
Acoustics
N/A
|
Ceiling
ACC
ACOUSTIC CEILING TYPEStandard ceiling Refer to DG / CEILING |
Communications
AV
AUDIO VISUAL REQUIREMENTSAudio visual facilites are required. Refer to DG / COMMUNICATIONS |
Cooling
N/A
|
Doors
DT
DOOR TYPESolid door to adjacent home base Refer to DG / DOORS |
Drainage
N/A
|
Fire Protection
FD
FIRE DETECTION/ALARMSFire detection/alarms to comply with NCC. Refer to DG / THERMAL/SMOKE DETECTORS FIRE HOSE REELFire Hose Reels as required to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT |
Floor
FF
FLOOR FINISHC - Carpet (As for Home Base) or alternatively SV - Sheet Vinyl (non foam backed) if Store opens onto similar finished space. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed to differ (KD) Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Store (ST) Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
N/A
|
|
Security
C
SECURITY LEVEL CCategory C - Medium Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"STORE" Refer to DG / DOOR SIGNS SIGNS GENERAL"FIRE EXTINGUISHER IN STORE ROOM" to external face of door to store room if Extinguisher inside. Refer to DG / SIGNS |
Ventilation
N/A
|
Wall
N/A
|
Water
N/A
|
Windows
N
WINDOWS - NWindows are not required for this space. WINDOWS - OTHERWhen windows are provided include obscure glazing and security grills Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |