Technical Data
Acoustics
N/A
|
Ceiling
RES
RESISTANCENon absorbent, water resistant ceiling. Refer to DG / CEILING CEILING - OTHERWalls and ceiling to be sealed, room enclosure must provide dry storage. Refer to 'Suggested Fixtures' list and SG / METALWORK / CEILING HOOK |
Communications
CO
COMMUNICATIONS/TELEPHONE POINTS1 double data point required. Refer to DG / COMMUNICATIONS |
Cooling
N/A
|
Doors
DT
DOOR TYPESolid door. Refer to DG / DOORS |
Drainage
N/A
|
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCC - Steel troweled Concrete floor. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed to Differ (KD). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Stores (ST). Refer to SG / DOOR HARDWARE / KEYING |
Light
DL
DAYLIGHTDaylight is recommended for this space. |
Power
GPO
GENERAL POWER OUTLETS1 double socket outlet. Refer to DG / POWER |
|
Security
D
SECURITY LEVEL DCategory D - Moderately High Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"ARCHIVE STORE" Refer to DG / DOOR SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION |
Wall
OTH
WALL - OTHERWalls and ceiling to be sealed, room enclosure must provide dry storage Refer to SG / LINING |
Water
N/A
|
Windows
N
WINDOWS - NWindows are not required for this space. WINDOWS - OTHERWindows are not to be included. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |