Technical Data
Acoustics
N/A
|
Ceiling
OTH
CEILING - OTHERCeilings to be easy clean with all joints sealed. Refer to 'Suggested Fixtures' list and SG / METALWORK / CEILING HOOK ACOUSTIC CEILING TYPEStandard ceiling. Refer to DG / CEILING |
Communications
CO
COMMUNICATIONS/TELEPHONE POINTSData points required. Refer to DG / COMMUNICATIONS |
Cooling
FAN
FANFan required. Refer to DG / COOLING POLICY / CEILING / WALL FANS |
Doors
DT
DOOR TYPESolid door Security Category C. Refer to DG / DOORS |
Drainage
OTH
DRAINAGE - OTHERTrade waste drainage to grease arrestor. Refer to DG / DRAINAGE TRADE WASTE DRAINAGE FIXTURES2 trade waste drainage outlets. Refer to DG / DRAINAGE |
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHISF - Industrial sheet flooring (Safety floor). Refer to DG / FLOOR FLOOR - OTHERCoved skirting to floor at wall. Refer to DG / FLOOR |
|
Heating
H
HEATINGProvide heating where regionally appropriate. Refer to DG / HEATING |
Illumination
LUX
LUX LEVEL240 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed Alike Canteen (CAN). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGNot Master keyed (NMK). Refer to SG / DOOR HARDWARE / KEYING |
Light
DL
DAYLIGHTDaylight is recommended for this space. |
Planning
m^2
AREAType 1 - 13m2 Type 2 - 12m2 Type 4 - 10m2 Refer to DG / AREA PLANNING - OTHERPositioned adjacent to Canteen if positioned adjacent to hall may need to be part of Entertainment Venue design or fire separated from Hall. Refer to Design Guide. Must comply with health regulations for food service. To be vermin proof and non-vermin harbouring. Refer to DG / AREA PROPORTIONTo suit number of servery openings and equipment. Refer to DG / AREA |
Power
GPO
GENERAL POWER OUTLETS2 double socket outlets. Refer to DG / POWER |
Security
C
SECURITY LEVEL CCategory C - Medium Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE"OFFICE/STORE" Refer to DG / DOOR SIGNS |
Ventilation
OTH
VENTILATION - OTHERGeneral Exhaust required. Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHERRendered and painted masonry walls. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
N/A
|
Windows
OTH
WINDOWS - OTHERIf windows are included obscure glazing and security grills are required. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |