Technical Data
Acoustics
N/A
|
Ceiling
NC
RES
RESISTANCENon absorbent, water resistant ceiling . Refer to DG / CEILING CEILING - OTHERCeilings to be easy clean with all joints sealed. Refer to 'Suggested Fixtures' list and SG / METALWORK / CEILING HOOK ACOUSTIC CEILING TYPEStandard ceiling. Refer to DG / CEILING |
Communications
CO
COMMUNICATIONS/TELEPHONE POINTS1 double data point required. Refer to DG / COMMUNICATIONS AUDIO VISUAL REQUIREMENTSAudio visual intercommunication facilites may be required. Refer to Design Guide and individual project brief. Refer to DG / COMMUNICATIONS |
Cooling
FAN
FANFan required. Refer to DG / COOLING POLICY / CEILING / WALL FANS |
Doors
DT
DOOR TYPESolid external door with external fly and vermin Screen door. Door to Office Security Category C. Refer to DG / DOORS |
Drainage
OTH
DRAINAGE - OTHERTrade waste drainage to grease arrestor. Refer to DG / DRAINAGE TRADE WASTE DRAINAGE FIXTURES2 trade waste drainage outlets Refer to DG / DRAINAGE |
Fire Protection
PFE
PORTABLE FIRE EXTINGUISHER/ BLANKETPortable fire extinguisher/fire blanket - to comply with NCC. FIRE HOSE REELFire Hose Reels as required to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT |
Floor
FF
FLOOR FINISHISF - Industrial sheet flooring (Safety floor). Refer to DG / FLOOR FLOOR WASTEFloor waste(s) are to be included with falls in floor. Refer to DG / DRAINAGE (& TRADE WASTE) FLOOR - OTHERCoved skirting to floor at wall and plinths. Solid plinth under benches Falls to floor waste located adjacent to basin. Refer to DG / FLOOR |
|
Heating
H
HEATINGProvide heating where regionally appropriate. Refer to DG / HEATING |
Illumination
LUX
LUX LEVEL240 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed Alike Canteen (CAN). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGNot Master keyed (NMK). Refer to SG / DOOR HARDWARE / KEYING |
Light
DL
DAYLIGHTDaylight is recommended for this space. |
Planning
m^2
AREAType 1 - 54m2 Type 2 - 45m2 Type 4 - 32m2 Refer to DG / AREA PLANNING - OTHERif positioned adjacent to hall may need to be part of Entertainment Venue design or fire separated from Hall. Refer to Design Guide. Must comply with health regulations for food service. To be vermin proof and non-vermin harbouring. Refer to DG / AREA PROPORTIONTo suit number of servery openings and equipment. Refer to DG / AREA |
Power
N/A
|
Security
D
SECURITY LEVEL DCategory D - Moderately High Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS CCTV CAMERASCCTV cameras are required in this space. Refer to DG / SPECIAL ELECTRICAL SYSTEMS |
Signs
DSF
DOOR SIGNAGE"CANTEEN" Refer to DG / DOOR SIGNS SIGNS - OTHER2 Prohibition signs "No Smoking" symbol, in conspicuous positions on opposite walls. Refer to DG / SIGNS SIGNS GENERALWARNING/SAFETY SIGNS Notice "DEEP FAT FRYING IS NOT PERMITTED IN THIS FACILITY UNLESS AT LEAST ONE WET FOAM EXTINGUISHER OF NOT LESS THAN 7 LITRES CAPACITY (FOR USE WITH COOKING FAT AND OILS-CLASS F) IS PROVIDED ADJACENT TO THE DEEP FAT FRYING APPLIANCE", in a conspicuous position. Symbol "Hand Wash", above basin. Sign with red writing and symbol “Warning – this fixture may deliver hot water which will scald.” -adjacent to the sink/basins. Refer to DG / SIGNS |
Ventilation
EXH
GENERAL EXHAUSTGeneral Exhaust required. Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHERRendered and painted masonry walls. 450mm high splashback to Benches, Sinks and Basins. Refer to SG/LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
HW
HOT & TEMPERED WATERHot water required to 1 x sink, tempered water required to basin. Refer to DG / WATER COLD WATERRequired to 1 x sink, 1 x BWU, 1 x dishwasher. Refer to DG / WATER |
Windows
Y
WINDOWS - YWindows are required for this space. |