Technical Data
Acoustics
N/A
|
Ceiling
OTH
CEILING - OTHERTranslucent openings in ceiling to provide natural lighting. Refer to 'Suggested Fixtures' list and SG / METALWORK / CEILING HOOK |
Communications
N/A
|
Cooling
N/A
|
Doors
N/A
|
Drainage
OTH
DRAINAGE - OTHERDish drain to perimeter, fall to openings. Refer to DG / DRAINAGE SANITARY DRAINAGE FIXTURES1 drainage outlet. Refer to DG / DRAINAGE |
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCC - Steel troweled Concrete floor well graded to enable hosing out. Refer to DG / FLOOR FLOOR - OTHERGrade floor to perimeter dish drain. Refer to DG / FLOOR |
|
Heating
H
HEATINGProvide heating where regionally appropriate. Refer to DG / HEATING |
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROL |
Keying
KY
KEYING GENERALKeyed Alike Agriculture Unit (AG). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Learning Spaces (LS). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
GPO
GENERAL POWER OUTLETS2 double socket outlets. Refer to DG / POWER |
|
Security
A
SECURITY LEVEL ACategory A - Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
N/A
|
Ventilation
OTH
VENTILATION - OTHERRefer to DG / VENTILATION |
Wall
OTH
WALL - OTHERWalls to be water resistant. Refer to SG / LINING |
Water
CW
COLD WATERRequired to 1 x hose cock. Refer to DG / WATER |
Windows
OTH
WINDOWS - OTHERTranslucent openings for natural light, favouring winter penetration, but excluding light exceeding a saturation level of 25 kilolux. Blue and red light should not be excluded by green only transmitting materials. Refer to DG / WINDOWS |