Technical Data
Acoustics
N/A
|
Ceiling
N/A
|
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPE1m minimum clear width Solid door with 20mm clearance at base. Refer to DG / DOORS |
Drainage
N/A
|
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCC - Steel Trowel Concrete. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed to Differ (KD). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Stores (ST). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
GPO
GENERAL POWER OUTLETSFor guidelines refer to Design Guide. Refer to DG / POWER |
|
Security
D
SECURITY LEVEL DCategory D - Moderately High Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGE" POTTERY STORE". Refer to DG / DOOR SIGNS SIGNS GENERALSAFETY NOTICE Hazardous Materials sign "FLAMMABLE LIQUID" - class 3, on the exterior of door. Refer to DG / SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION |
Wall
N/A
|
Water
N/A
|
Windows
N
WINDOWS - NWindows are not required for this space. WINDOWS - OTHERIf windows are included obscure glazing and security grills are required. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |