Technical Data
Acoustics
N/A
|
Ceiling
|
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEGrill and Grill Gate for maximum ventilation. 1m wide door opening to outdoor workshop. Refer to DG / DOORS |
Drainage
N/A
|
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCC - Steel Trowel Concrete. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
N/A
|
Keying
KY
KEYING GENERALKeyed Alike - Visual Arts (VA). Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Learning Spaces (LS). Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
N/A
|
|
Security
B
SECURITY LEVEL BCategory B - Moderately Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
SIG
SIGNS GENERALSAFETY NOTICE Warning sign "HOT OBJECTS" adjacent to Kiln in a conspicuous position. Refer to DG / SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION SPECIAL EXHAUSTSpecial Exhaust required. Refer to DG / VENTILATION |
Wall
FR
FIRE RATED WALLWALL - OTHERNon-combustible wall lining. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
N/A
|
Windows
OTH