Technical Data
Acoustics
N/A
|
Ceiling
FR
OTH
CEILING - OTHERFire rated ceiling FRL 120/120/120 or walls to extend to roof level. Refer to 'Suggested Fixtures' list and SG / METALWORK / CEILING HOOK |
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEOutward Opening Fire Rated Door (FRL --/120/30) with Security Category C. Refer to DG / DOORS |
Drainage
OTH
DRAINAGE - OTHERTrade waste drainage to dilution pit. Refer to DG / DRAINAGE (& TRADE WASTE). TRADE WASTE DRAINAGE FIXTURES1 trade waste drainage outlet. Refer to DG / DRAINAGE (& TRADE WASTE). |
Fire Protection
PFE
PORTABLE FIRE EXTINGUISHER/ BLANKETPortable fire extinguisher and fire blanket are required. May be located outside room, adjacent to door. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT FIRE HOSE REELFire Hose Reels as required to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT |
Floor
FF
FLOOR FINISHCC - Steel Trowelled Chemical Resistant Concrete Finish with Coved skirting to walls and graded towards acid bay. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
|
Keying
KY
KEYING GENERALKeyed to Differ (KD). Refer to SG455 / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Stores(ST). Refer to SG455 / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
N/A
|
|
Security
D
SECURITY LEVEL DCategory D - Moderately High Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS SECURITY - OTHERDoor to be Security Category C. Refer to DG / SAFETY (ACCIDENT AVOIDANCE) & GENERAL SECURITY. |
Signs
DSF
DOOR SIGNAGE"CHEMICAL STORE". Refer to DG / DOOR SIGNAGE. SIGNS GENERALSAFETY SIGNAGE Hazard danger sign "ACID", above or adjacent Acid Bay. Prohibition sign "No Smoking" symbol, in a conspicuous position. Notice "100 LITRE MAXIMUM FLAMMABLE LIQUID STORAGE" on Cupboard for Flammable Liquids. Prohibition sign "No Smoking" symbol on the exterior of door. Hazard danger sign "HAZARDOUS CHEMICALS" on the exterior of door. Hazardous Materials sign "FLAMMABLE LIQUID" - class 3, on the exterior of door. Refer to DG / SIGNS |
Ventilation
EXH
GENERAL EXHAUSTRefer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION |
Wall
FR
FIRE RATED WALLWALL - OTHERFire Rated Walls (FRL 120/120/120) Corrosion Resistant masonry walls to acid bay. Refer to SG / LINING |
Water
CW
COLD WATERRequired to 1 x hose cock. Refer to DG / WATER. |
Windows
N
WINDOWS - NWindows are not required for this space. WINDOWS - OTHERWhen windows provided they must have obscure glazing and security Grills. Refer to DG / WINDOWS
VISUAL PRIVACYVisual privacy is required from other spaces. |