Technical Data
Acoustics
N/A
|
Ceiling
N/A
|
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEMinimum 1.5m wide roller shutter for easy access Refer to DG / DOORS DOOR FRAME TYPEInclude external gate or grill for security Refer to DG / DOORS |
Drainage
N/A
|
Fire Protection
PFE
PORTABLE FIRE EXTINGUISHER/ BLANKETPortable fire extinguisher/fire blanket - to comply with NCC. |
Floor
FF
FLOOR FINISHSteel troweled concrete Refer to DG / FLOOR FLOOR - OTHERMinimum threshold at door to enable equipment access. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed differently (key to differ) Refer to SG455 / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Maintenance & Cleaning Refer to SG455 / DOOR HARDWARE / KEYING |
Light
N/A
|
Power
GPO
GENERAL POWER OUTLETS1 double socket outlet Refer to DG / POWER |
|
Security
D
SECURITY LEVEL DCategory D - Moderately High Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGEDoor signage required. Suggested text "Store" Refer to DG / SIGNS |
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION |
Wall
IR
IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
N/A
|
Windows
N
WINDOWS - NWindows are not required for this space. VISUAL PRIVACYVisual privacy is required from other spaces. |