Technical Data
Acoustics
R2R
ROOM TO ROOM NOISENoise to and from adjacent rooms should be considered. |
Ceiling
RES
RESISTANCEWater resistant ceiling required. Refer to DG / CEILING |
Communications
N/A
|
Cooling
N/A
|
Doors
DT
DOOR TYPEExternal door to be grill gate. Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURESDrainage outlet(s) required. Refer to DG / DRAINAGE |
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCeramic tiled floor finish. Refer to DG / FLOOR FLOOR WASTEFloor waste(s) are to be included with falls in floor. Refer to DG / DRAINAGE (& TRADE WASTE) FLOOR - OTHERCoved skirting for easy cleaning. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVEL160 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide.| Refer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed alike - Toilets. Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff. Refer to SG / DOOR HARDWARE / KEYING |
Light
N/A
|
Planning
m^2
AREAArea depending upon the facilities needed for student numbers. Refer to DG / AREA PLANNING - OTHERConsider visual privacy, sight lines to mirrors and noise impact. Include at least one ambulance accessible WC cubicle (2m wide) per sex for each general student toilet group. For area allowance and number of fittings refer to the Accommodation Summary. Refer to DG / AREA |
Power
GPO
GENERAL POWER OUTLETSGeneral power outlets required. Refer to DG / POWER |
Security
A
SECURITY LEVEL ACategory A - Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
DSF
DOOR SIGNAGETOILET Braille & Tactile Door Sign or "AMBULANT TOILET" Braille & Tactile Door Sign to each cubicle. Refer to DG / DOOR SIGNS |
Ventilation
OTH
EXHAUST - OTHERRefer to Design Guide for specific ventilation requirements of toilets. Refer to DG / VENTILATION NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION GENERAL EXHAUSTMechanical Exhaust of toilet areas may be required. Refer to DG / VENTILATION |
Wall
OTH
WALL - OTHERSplashback 300mm high to basin/washtrough (preferably stainless steel). Water and impact resistant to 2100mm high; brickwork is preferable for easy cleaning. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
CW
COLD WATERRequired to WCs. Refer to DG / WATER |
Windows
OTH
WINDOWS - OTHERFixed metal louvres preferred for visual privacy. Refer to DG / WINDOWS VISUAL PRIVACYVisual privacy is required from other spaces. |