Technical Data
Acoustics
NL
NOISE LEVELSNoise levels within this space should be considered. Refer to DG / ACOUSTICS / INTERNAL NOISE LEVELS ROOM TO ROOM NOISENoise to and from adjacent rooms should be considered. ROOM ACOUSTICSRoom acoustics, particularly reverberation time should be considered. |
Ceiling
ACC
ACOUSTIC CEILING TYPEStandard ceiling. Refer to DG / CEILING |
Communications
CO
COMMUNICATIONS/TELEPHONE POINTS3 double data points required. Refer to DG / COMMUNICATIONS AUDIO VISUAL REQUIREMENTSAudio visual facilites are required. Refer to DG / COMMUNICATIONS WIRELESS ACCESS POINTS |
Doors
DT
DOOR TYPEAt least one door to circulation space. Type 1 - 2.4m Acoustic (Rw 45) accordian operable wall to Staff Room Types 2 & 3 - 3.6m Acoustic (Rw 45) accordian operable wall to Staff Room. Refer to DG / DOORS ACOUSTIC RATED DOORSAcoustic rated doors are required. |
Drainage
N/A
|
|
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHCarpet finish. Refer to DG / FLOOR |
Gas
N/A
|
Heating
H
HEATINGProvide heating where regionally appropriate. Refer to DG / HEATING |
Illumination
LUX
LUX LEVEL240 lux. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide Refer to DG / LIGHTING. |
Keying
KY
KEYING GENERALKeyed alike - Staff Study. Refer to SG / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Administration & Staff. Refer to SG / DOOR HARDWARE / KEYING |
Light
DL
DAYLIGHTDaylight is recommended for this space. |
Planning
m^2
AREAType 1 - 13 m2 for Core seven. Type 2 - 19 m2 for Core fourteen. Type 3 - 28 m2 for Core twenty one. Refer to DG / AREA PLANNING - OTHERConnected to Staff Room (PS602.01). Refer to DG / AREA PROPORTIONFor Type 1, square or maximum X:Y, 1:1.2 For Type 2 and Type 3, rectangular proportions of approximately 1:5 Refer to DG / AREA |
Power
CM
CABLE MANAGEMENTCable management to be considered. Refer to DG / POWER GENERAL POWER OUTLETS2 double socket outlets. Refer to DG / POWER |
Security
B
SECURITY LEVEL BCategory B - Moderately Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS |
Signs
N/A
|
Ventilation
NV
NATURAL VENTILATIONProvide Natural Ventilation. Refer to DG / VENTILATION and DG / AIR MOVEMENT / NATURAL VENTILATION |
Wall
PF
PINBOARD FINISHMaximise pinboard finish to 2100mm. Not required above splashback. Refer to SG / LINING |
Water
N/A
|
Windows
Y
WINDOWS - YWindows are required for this space. |