Technical Data
Acoustics
NE
NOISE EMISSIONNoise emission from this space to the external environment should be considered. |
Ceiling
RES
RESISTANCEImpact resistant ceiling required. Refer to DG / CEILING ACOUSTIC CEILING TYPEAcoustic absorptive ceiling (A). Refer to DG / CEILING |
Communications
CO
COMMUNICATIONS/TELEPHONE POINTSCommunications/Telephone point requirements and considerations apply. Refer to DG / COMMUNICATIONS |
Cooling
N/A
|
Doors
DT
DOOR TYPEPossible motorised Sectional Overhead Door or equivalent from Communal Space, opening 3m high x max 8m wide. Refer to DG / DOORS |
Drainage
SD
SANITARY DRAINAGE FIXTURESOnly for Type 4 (1 drainage outlet) and Type 5 (1 drainage outlet). Refer to DG / DRAINAGE |
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHPaving generally. Central area to be relatively flat. Refer to DG / FLOOR FLOOR - OTHERCentral area is to be kept dry during wet weather, no water collection, drains or sumps within that area. Surface water collection to be kept to the periphery. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
LUX
LUX LEVELLux level considerations must be taken into account. Refer to DG / LIGHTING LIGHTING CONTROLLighting control requirements as outlined in Design Guide. Refer to DG / LIGHTING |
Keying
N/A
|
Light
N/A
|
Planning
m^2
AREA Type 3 - 75 m2 for Core seven Type 4 - 150 m2 for Core fourteen Type 5 - 210 m2 for Core twenty one Refer to DG / AREA PLANNING - OTHERCentral area to be relatively flat and dry during wet weather Surface drainage to fall to the outside. This space can be combined with corresponding Canteen Servery Covered Areas (PS604.21) according to Core size This area is related to Home Base units (PS401, PS430, PS440) Consider pedestrian circulation to minimise erosion Consider unfavourable prevailing winds. Refer to DG / AREA PROPORTIONRectangular proportions for Type 3, Type 4 and Type 5. |
Power
N/A
|
Security
N/A
|
Signs
N/A
|
Ventilation
N/A
|
Wall
N/A
|
Water
CW
COLD WATER |
Windows
N/A
|