Published: 2018-02-15 13:58:59 - Exported: 2024-09-04 16:45:04 | NB | The information on this sheet once printed/exported is classed as an uncontrolled copy. The currency of the information should be checked by visiting the ESFG website prior to using the information for any purposes.
Published: 2018-02-15 13:58:59 - Exported: 2024-09-04 16:45:04 | NB | The information on this sheet once printed/exported is classed as an uncontrolled copy. The currency of the information should be checked by visiting the ESFG website prior to using the information for any purposes.
GUIDE NOTE: Refer to Design Guide sections DG/ FABRIC, DG/ MATERIALS AND FINISHES, DG/ WALLS, DG/ CEILING
As per current NATSPEC except as follows:
General
Requirement: Comply with BCA Specification C1.10a which sets out requirements in relation to the fire hazard properties of wall and ceiling linings.
Wall and ceiling linings must comply with BCA Specification C1.10a Table 3, Wall and Ceiling Lining Materials (Material Groups Permitted).
As per current NATSPEC except as follows:
Plasterboard
Impact resistant plasterboard
Description: Purpose designed mesh-reinforced plasterboard to withstand a high degree of “soft body impact”.
Standards: Generally to AS/NZS 2588
Thickness: 13mm
Sheet Density (nominal): 10.0 kg/m2
Edge finish: Recessed.
Identification: Coloured face paper or stamped on back to identify that the plasterboard sheets are especially designed to be soft body impact resistant.
Corrugated and perforated metal ceiling lining – standard profile
Type: Proprietary perforated and roll-formed corrugated steel zincalume sheet and purpose made accessories forming part of a system to AS 1562.1.
Material: Pre-painted and organic film/laminate products: To AS 2728, Category 3 or 4 as appropriate to all ceiling sheets/panels and metal trims.
Thickness: 0.42 mm (minimum) B.M.T. (Base Metal Thickness)
Corrugation depth: 16 mm (minimum)
Acoustic blanket: Polyester fibre black lined acoustic blanket manufactured from thermally bonded polyester.
Corrugated and perforated metal ceiling lining – mini profile
Specify the appropriate acoustic blanket to suit the requirements of the room.
Type: Proprietary perforated and roll-formed corrugated steel zincalume sheet and purpose made accessories forming part of a system to AS 1562.1.
Material: Pre-painted and organic film/laminate products: To AS 2728, Category 3 or 4 as appropriate to all ceiling sheets/panels and metal trims.
Thickness: 0.42 mm (minimum) B.M.T. (Base Metal Thickness)
Corrugation depth: 6 mm (minimum).
Acoustic blanket: Polyester fibre black lined acoustic blanket manufactured from thermally bonded polyester.
Type: 13mm thick perforated plasterboard sheet.
Plasterboard: To AS/NZS 2588
Acoustic blanket: Polyester fibre black lined acoustic blanket manufactured from thermally bonded polyester.
GUIDE NOTE: Standard MDF board must not be used as a wallboard lining or backing/ substrate (excluding lining to operable walls).
Fibre cement
Plywood and blockboard
General: Plywood and blockboard wallboard lining must be treated to prevent the attack of termites, to AS 1604.3- H2 and AS 2270.
As per current NATSPEC except as follows:
Register (ceiling grille)
Canteen ceilings to be sealed from dust and vermin. to avoid dust problems within canteens Roof ventilators should only ventilate the roof space.
Refer to SG / ROOFING
Minimum size: The width and breadth of the register (grille) must be equal to the diameter of the rotary ventilator throat. (e.g. 400 mm diameter rotary ventilator throat requires a 400 x 400 mm register).
Timber trim
GUIDE NOTE: Timber trims must be in a termite resistant timber species or be preservative treated against termite attack.. Refer to timber products, finishes and treatment.
Seasoned hardwood: AS 2796.1
Naturally termite resistant timbers: To 3660.1 Appendix C
Grade:
>
Cypress Pine: AS 1810
Preservative treated timber: AS 1604.1 (class H2 minimum)
MDF: Must not to be used
As per current NATSPEC except as follows:
The selection of materials and finishes must be based on a knowledge of the activities to be conducted in the area. Lining selections should be based on the following performance criteria:
4.1 Sheet Lining
Linings schedule
Framed walls in toilets/showers areas to be lined with
9 mm fibre cement sheeting.
Location
>
Alternative 1
Description: Proprietary parallel interlocking steel structural panels system
Profile size: 300 x 50 x 1 mm thick.
Protective finish: Galvanized
Wall fixing angles: 50 x 50 x 3.2 mm thick steel
Installation:
Screw fixing to ceiling structure.
Double screw fix using 2 mm thick large washers at maximum 600 mm centres to ceiling structure. Pop rivet fix to perimeter wall angles.
OR
Alternative 2
Description: Wall security mesh
Open Area: 85%
Nominal Size of Mesh: LWM: 100 mm
SWM: 50 mm
Nominal Strand Size: Width: 4.0 mm
Thick: 2.0 mm
Weight: 2.5 kg/sq.m
Refer to EFSG DG / SECURITY CATEGORY OF OPENINGS and room technical data.
Location
>
General: Where additional security is required in framed buildings fix one of the alternative linings securely to designated framed walling.
Alternative 1
Wall security mesh
Open Area: 85%
Nominal Size of Mesh: LWM: 100 mm
SWM: 50 mm
Nominal Strand Size: Width: 4.0 mm
Thick: 2.0 mm
Weight: 2.5 kg/sq.m.
Alternative 2
Proprietary aluminium zinc coated steel sheet permanently bonded to fibre cement sheeting.
Intruder resistance: To AS 3555.1 - Level 6
Fibre cement sheeting
Aluminium zinc coated steel sheet
Laminating: The bonding of the steel sheet product to the fibre cement must be undertaken by the manufacturer under factory controlled conditions. Bonding of the materials must not be undertaken on site.
GUIDE NOTE: Add the following subclauses to "Selections" nominated in NATSPEC Building Template/worksection
Do not use Organic FIBREBOARD as a pinboard wall lining.
Location
Bottom edge: Floor height (skirting fixed over face of board).
Top edge: Ceiling springing height 2700 mm maximum.
Extent: Shown on drawings.
Location
Bottom edge: 900mm from floor or top of splashback
Top edge: 2100 mm (nominally) level with top of door head
Extent: Shown on drawings
Location
Bottom edge: 900mm from floor
Top edge: 2100 mm (nominally) level with top of door head
Extent: Shown on drawings
Location
Bottom edge: 900mm from floor
Top edge: Ceiling
Extent: Shown on drawings
Location
Generally:
Bottom edge: Floor level.
Top edge: 2100 mm (nominally) level with top of door head.
Extent: Shown on drawings.
Location
Bottom edge: Floor height (skirting fixed over face of board)
Top edge: 2100 mm (nominally) level with top of door head
Extent: Shown on drawings. Do not install behind heaters
GUIDE NOTE: As an alternative, the top edge of the pin board wall lining may be nominated to finish at ceiling height.
Type
Commercial wall fabric facing bonded to resilient 100% polyester or resilient multiple foam pinning substrate adhered to a plywood backing.
Facing fabric and pining substrate and must be able of hold pins/staples firmly and capable of maintaining its pin holding capacity over a prolonged period of constant use.
Substrate
Description: Plywood wall lining which has been treated to prevent attack by termites.
Thickness: 6.5 mm
Ply: 5
Stress grade: F14
Standards:
To AS 2270
AS 1604.3, Hazard class H2
Identification: Each sheet of ply to be stamped on the back to identify that it has been treated to prevent the attack of termites to the appropriate Australian Standard.
OR
Substrate, impact-resistant
Description: Plywood wall lining which has been treated to prevent attack by termites.
Thickness: 7.5mm
Ply: 5
Stress grade: F11
Standards:
To AS 2270
AS 1604.3, Hazard class H2
Identification: Each sheet of ply to be stamped on the back to identify that it has been treated to prevent the attack of termites to the appropriate Australian Standard.
Fire Resistance – Fire Hazard Properties
Pinboard wall lining composite: The pinboard wall lining composite (i.e. fabric bonded to the resilient pining substrate with plywood backing) must comply with the BCA Fire Hazard Properties Specification C1.10a. The composite must achieve the required Group 1, Group 2 or Group 3 rating
Requirement: The bonding of the fabric faced resilient backed product to the wallboard lining substrates must be undertaken by the manufacturer prior to delivery, bonding of the materials must not be undertaken on site.
Procedure: The manufacturer using the following method must apply the fabric faced resilient backed material to the wallboard lining substrate.
Water Based Adhesive:
Order and confirm delivery instructions with the supplier not less than 6 weeks prior to the date required.
Fixing
Fix the pin board wall lining (includes: fabric, resilient backing and lining substrate) to the wall frame/masonry wall in accordance with the manufacturer’s recommendations.
Joints: Butt.
Exposed ends
Finish
Colour:
Compliance
Provide a certificate of compliance to certify that the pinboard wall lining including the plywood backing complies with the manufacturing procedures detailed in this specification.
Distribution: Hand one copy to the Principal’s Authorised Person / Principal’s Representative
Proprietary items
BCR Holdings
Take Notice Manufacturers Pty Ltd:
Gilkon Australia
Type
Impact resistant non-combustible lining.
Corrugated Metal Lining
Location
Generally
Provide perforated/unperforated corrugated metal wall lining from 2143mm above finished floor level.
Type
Colour: Off white
Black liner and thermally bonded textile purpose designed acoustic blanket.
General: Provide a removable panel to allow access to the adjustable overhead track for each operable wall.
Refer to SG / ROOM DIVIDERS