As per current NATSPEC except as follows:
Supply and installation
The Selections indicate proprietary fixtures, fittings and equipment (FFE). All items are identified with a group number which indicates who is responsible for the item according to a construction industry accepted description as follows.
Group |
Description |
1 |
Provided and installed by the Contractor |
2 |
Provided by the Principal and installed by the Contractor |
3 |
Provided and installed by the Principal |
Installation
Allow to supply and install all Group 1 items
Group 2 items
Receive delivery of the items of Furniture, Fixtures and Equipment (FFE) at the normal site delivery point for convenient off-loading. The delivery point must be agreed to by the contractor and nominated FF&E supplier.
General
Supply, install all Sundry items accordance with manufacturer’s instructions and carry out operational testing of the items as specified in this subsection.
As per current NATSPEC except as follows:
GUIDE NOTE: Create a new subsection.
Supply
Group 1
Type 2 (staff only)
Type 3 (Ambulant cubicles and access WCs)
GUIDE NOTE: GUIDE NOTE: Dispensers for Paper towel are for disabled toilets only. However, consideration must be given where necessary. Paper towels are not recyclable and generates waste.
Supply
Group 1
Standards
All fittings and installation for Access, Disabled and Self Help units must be in compliance with AS1428.1
Description
Roller type unit to suit 197 mm wide paper rolls. White baked enamel finish, fixed to wall where shown.
Supply
Group 1
Instructions
Clear instructions must be provided in accordance with the following:
ALTERNATIVE 1
Description
Pressure die-cast in aluminium body pump action soap dispenser
Soap valve: Corrosion resistant with a delivery system.
Fixing
ALTERNATIVE 2
Description
Supply
Group 1
Stainless steel surface mounted lockable body pump action soap dispenser.
Instructions
Supply
Group 1
Location
>
GUIDE NOTE: Insert project specific locations.
Group 1
>
Supply
Group 1
>
Type
Metal fold away shower seat with epoxy coated seat slats and safety spring clutch mechanism.
To the manufacturer's recommendations
Supply
Group 1
Description
White plastic waste bin with swing top waste container
Supply
Group 1
>
Supply
Group 1
>
Number of flagpoles: 2 per School.
Aluminium flagpole, machine tapered, hot dipped galvanised steel spigot and base plate, complete with “anti-vandal” internal halyard systems and all fittings required to fly flags.
As per current NATSPEC except as follows:
Supply
Group 1
Type
One complete proprietary system must be used (mandatory) for all floor inserts and net posts (do-not use a mixture of different proprietary products).
Location
Gymnasium Size:
>
As shown on Drawings.
Types
Volleyball post sockets
Description
Zinc plated steel proprietary inserts
Recessed flush with floor surface.
Location
GUIDE NOTE: Insert project specific locations. Refer to the Educational Facilities Standards and Guidelines.
As shown on Drawings.
Proprietary post in mild steel complete with welded closed ends, stays, locking stud and bearing pad/s all in accordance with the International Badminton Federation.
Fit proprietary compatible floor sockets
Protective coating and paint system by manufacturer prior to delivery.
Location
>
As shown on Drawings.
Description
Proprietary post in mild steel complete with base to fit floor sockets, locking device and bearing pad/s all in accordance with the Australian Volleyball Federation requirements.
Adjustable
Hooks (if applicable):
Welded (fitted to upper section)
One (to tension top of net)
Fit proprietary compatible floor sockets
Finish
Protective coating and paint system by manufacturer prior to delivery.
Location
>
As shown on Drawings.
Proprietary post in mild steel with net and ring complete with base to fit floor sockets, locating pin, locking device and bearing pad/s all in accordance with Netball Australia requirements.
60mm diameter pipe
3050mm
Protective coating and paint system by manufacturer prior to delivery.
Description: 15mm high density close cell foam covered with heavy-duty nylon reinforced vinyl netball post padding
Selection
Select appropriate type of backboard (see below) either (A), (B), or (C).
Installation
In line with manufacturers recommendations. Structural certification is required for all proprietary items. This certification will cover all materials, connections, attachment points, fixings and installations including static and active loads. All certification is to be provided at hand-over as part of final documentation.
Location
Gymnasium
Proprietary framework to support backboard frame and net at correct height in a fixed position. Supply and install all brackets and fixings as per the manufacturers recommendations.
Fix framework securely to brickwall/structural steel in accordance with engineers requirements. The backboard support frame to be welded together with all joints mitred and ends welded closed. Provide diagonal braces across and between support arms. The cantilevered backboard should not exceed 1200mm from the fixing location.
Colour
Location
Gymnasium
Proprietary framework to support backboard and net at correct height. Allow backboard to be raised with winch when not in use. Supply and install all cables, brackets, winch and pulleys as required.
Fix wall mounting frame securely to brickwall/structural steel in accordance with engineer’s requirements. The four moveable arms to be supplied with steel tube bearing type hinges that allows the back board to lift up. To support backboard at correct working height attach two 5mm diameter galvanised. steel cables with galvanised. steel turnbuckles and lock nuts to shackles on top of board, fix cables securely to wall or ceiling with cable brackets. Provide a 5mm diameter galvanised. steel hauling cable fixed to centre of backboard and a swivel anchor sheave block fixed to wall or frame in position to provide correct operation of the lift-up action of the backboard. Fix winch securely to wall or frame in correct operating position and install cable. The handle of the winch's worm drive must be operable for both down and up movements.
Finish
Protective coating and paint system by manufacturer prior to delivery
Colour
Location
Gymnasium
Description
Proprietary frame work to support backboard and net at correct height. Allow backboard to swing sideways when not in use. Supply and install all cables, brackets and fixings as required.
Fix wall mounting frame securely to brickwall/structural steel in accordance with engineers requirements.
Finish
Protective coating and paint system by manufacturer prior to delivery
Colour
Description
Provide a 22mm diam. Truline Supatough (23526) ring solid mild steel rod ring with provisions for net fastening. Fix ring to backboard assembly with a 150mm wide x 5mm thick steel plate cleat with two 10mm diam. steel rod braces. All in accordance with the Australian Basketball Federation requirements.
Protective coating and paint system by manufacturer prior to delivery.
Orange
Location
Gymnasium
Frame Description
Proprietary welded frame work with mitred corners and centre vertical member. Bolt holes pre drilled in frame for basketball ring. Provide lugs and if required cable fixing and hinges to connect backboard support.
Backboard Description
An approved moisture resistant custom wood backboard bolted to frame with 10mm diam. countersunk bolts equally spaced at 350mm maximum centres.
Support post
A proprietary outdoor basketball post system. The post is to be extended 750mm (minimum.) into a reinforced concrete footing and permanently secured by anchor pins or sleeve locking devices. The post/sleeve must be securely tied into the concrete to prevent any risk of the post rotating when under pressure from wind loading and/or live loads.
Protective padding, support post
Each post is to be supplied with removable cylindrical shaped protective padding.
Backboard
Cast aluminium fan shaped or full size waterproof/rotproof ply. Fixing position to be in accordance with the "The Official Basketball Rules" produced by Basketball Australia.
Rings
Truline Supatough (23526) ring with provisions for net fastening. Ring dimensions and fixing height to be in accordance with the "The Official Basketball Rules" produced by Basketball Australia.
Installation
Ring and backboard mounting must be bolted directly to backboard support plate with galvanised bolts washer and security type tamper proof shear nut sleeve assembly. The tamper proof nuts are to be designed to shear when sufficient torque is applied allowing the remaining protective sleeve to turn freely preventing removal.
Proprietary system
One proprietary system is to be used for the complete assembly of support post, backboard and ring. Do not use a mix of different manufacturers’ proprietary items.
Certification – Mandatory
The complete system including posts reinforced footings and assembly must be certified by a registered structural engineer (mandatory). Hand one copy of the certification to The Principal’s Authorised Person / Principal’s Representative
Description
Proprietary hot dipped galvanised steel tube insert with a hinged cap to seal top of insert when net holding posts removed.
Insert
Size (Minimum): 64mm ID x 5.2mm thick x 240mm long designed to receive compatible holding posts.
Requirement
Post and ring assembly
Post
Each post shall be a vertical 60mm O.D. tubular steel pipe, capped at the top and ragged or keyed at the bottom to prevent rotation when fixed in position. Terminate post 150mm from bottom of footings. Fixed posts set in concrete footing. Fix ring at the top of the post at 3050mm above the finished court surface level all in accordance with the Australian Netball Association.
Ring
Each post to be fitted with a 380mm I.D. circular ring of 15mm M.S. rod welded to a 10mm thick M.S. bracket, which shall help support the ring 150mm from the post (measured from internal edge of ring). Two 10mm diameter M.S. rod braces to be welded from each side of the M.S. bracket to each side of the ring all in accordance with the Australian Netball Association.
Location
Games Court
Footings
Fixed posts set in concrete footing to structural engineer’s design. The top of the footing to be a minimum of 5 mm above the finished surface (where the support post penetrates the concrete footing) and sloped the edges to drain water away from support post.
Certification - Mandatory
The complete system including posts reinforced footings and assembly must be certified by a registered structural engineer (mandatory). Hand one copy of the certification to the Principal’s Authorised Person / Principal’s Representative.
As per current NATSPEC except as follows:
GUIDE NOTE: Create a new sub section
Supply
Group 1
>
Electric oven with gas cooktop
GUIDE NOTE: Select appropriate gas type. Delete gas type not applicable.
Supply
Group 1
>
Supply
Group 1
>
Type
Bench top cooker, natural gas
Supply
Group 1
Type
Free standing heavy duty stainless steel commercial gas range with gas oven. Access to all parts via control panel.
GUIDE NOTE: Select appropriate gas type. Delete gas type not applicable.
Supply
Group 1
Location
>
Type
Free standing heavy duty stainless steel commercial gas range with electric oven. Access to all parts via control panel.
Supply
Group 1
>
Type
GUIDE NOTE: Insert job specific locations. Alter group number if required.
Supply
Group 1
Location
>
Type A
Supply
Group 1
Location
>
Type
Double boiling hot plate, single phase with 10 Amp with plug and flex.
Supply
Group 1
Location
>
Type
5 Lt Electric, automatic, wall mounted, non-drip outlet model with flex and plug.
Supply
Group 1
Location
>
Supply
>
Group
Location
>
Type
Supply
>
Group
>
Supply
>
Group
Location
>
Supply
>
Group
>
Type
Supply
>
Group
Location
>
Type
Supply
>
Group
>
Type
Supply
>
Group
Type
Supply
>
Group
>
Supply
>
Group
>
4.20 Pottery Wheel
Group
>
Description
Group
Group 1
Description
Description: Electric 240 volt 50Hz 10A hand dryer.
Housing: Cast Aluminium or Zinc Die Cast, with heavy duty powder coat white Finish.
Element: 2400 watts, protected by thermal overload switch.
Motor: 2 pole, with permanently lubricated ball bearings.
Timer: 45 second cycle.
Operation: Push button
Mounting Height To Underside:
Supply
Group 1
>
Type: A proprietary mechanical step lift designed to transport people with disabilities with or without wheelchair between two levels up to a height of 1000 mm.
Model
Check with the manufacturer/s to determine the current correct model for the specific location.
Delivery
Order and confirm delivery instructions with the supplier not less than 12 weeks prior to date required.
The lift installation and distance of power unit from the lift must be in accordance with the manufacturers requirements.
Group
Group 1
Location
>
General
Type: A proprietary electronic security barrier using magnetic detection principals. The unit will be microprocessor controlled and automatically adjust to its electronic environment. The system must be purpose designed for use in libraries.
Processor
Desensitiser/Re-sensitiser
General: A compatible proprietary desktop desensitiser/re-sensitiser.
Security Strips
Compatibility: The security system must have compatible security strips available that can be inserted in the spines of books and attached to electronic media (eg. CD’s and DVD’s).