Technical Data
Acoustics
N/A
|
Ceiling
RES
RESISTANCEImpact Resistant wire mesh ceiling. Refer to DG / CEILING |
Communications
N/A
|
Cooling
N/A
|
Doors
N/A
|
Drainage
N/A
|
Fire Protection
N/A
|
Floor
FF
FLOOR FINISHConcrete Pitch with bituminous covering. Area surrounding pitch to be grass. Refer to DG / FLOOR FLOOR - OTHERProvide adequate drainage pitch area. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
N/A
|
Keying
N/A
|
Light
N/A
|
Planning
m^2
AREA129.6m2 Refer to DG / AREA PLANNING - OTHEROpening should face away from buildings, car parking, footpaths playing fields or other occupied areas Run-up and area behind to be left clear of plantings. Refer to DG / AREA PROPORTIONOrientation: North-South where possible. Size overall: 18m x 7.2m. Pitch: 9m x 1.8m. Distance of 50m left clear in front of nets. Distance of 5m left clear behind nets, clear from boundary fences or similar. Perimeter fence minimum 3.4m high. Refer to DG / AREA |
Power
N/A
|
Security
N/A
|
Signs
N/A
|
Ventilation
N/A
|
Wall
OTH
WALL - OTHERBatting practice safety fence to sides and rear of practice pitch Perimeter fence height minimum 3.4m. Lower fence edge maximum 150mm above ground to enable grass maintenance. Refer to SG / LINING IMPACT RESISTANCEImpact resistant walls are recommended. Refer to DG / FABRIC |
Water
N/A
|
Windows
N/A
|