Technical Data
Acoustics
NL
NOISE LEVELSNoise levels within this space should be considered. Refer to DG / ACOUSTICS / INTERNAL NOISE LEVELS ROOM TO ROOM NOISENoise to and from adjacent rooms should be considered. ROOM ACOUSTICSRoom acoustics, particularly reverberation time should be considered. |
Ceiling
ACC
ACOUSTIC CEILING TYPENRC >0.85 highly absorptive ceiling. Refer to DG / CEILING |
Communications
CO
COMMUNICATIONS/TELEPHONE POINTSData points required. Refer to DG / COMMUNICATIONS AUDIO VISUAL REQUIREMENTSAudio visual requirements and considerations apply. Refer to DG / COMMUNICATIONS |
Cooling
N/A
|
Doors
DT
DOOR TYPEElectronic Security Gates/Barrier to Main Area. Refer to DG / DOORS |
Drainage
N/A
|
Fire Protection
FHR
FIRE HOSE REELFire Hose Reels as required to comply with NCC. Refer to DG / BUILDING REGULATIONS & BUILDING CODE OF AUSTRALIA / SERVICES AND EQUIPMENT |
Floor
FF
FLOOR FINISHCP- Carpet finish, to match adjacent area. Refer to DG / FLOOR |
Gas
N/A
|
Heating
N/A
|
Illumination
OTH
ILLUMINATION - OTHERRefer to DG / LIGHTING LUX LEVEL240 lux. Refer to DG / LIGHTING LIGHTING CONTROLRefer to DG / LIGHTING |
Keying
KY
KEYING GENERALKeyed alike - Library Facility (LIB). Refer to SG455 / DOOR HARDWARE / KEYING MASTER KEYINGMaster keyed - Library Facility (LIB). Refer to SG455 / DOOR HARDWARE / KEYING |
Light
DL
DAYLIGHTDaylight is recommended for this space. |
Power
GPO
GENERAL POWER OUTLETSRefer to DG / POWER |
|
Security
A
SECURITY LEVEL ACategory A - Low Security Level applies. Refer to DG / SECURITY CATEGORIES FOR OPENINGS CCTVCCTV monitoring of Library is required. Refer to DG / SPECIAL ELECTRICAL SYSTEMS SECURITY - OTHERInclude Security Alarm system to subsidiary exit doors when provided, with alarm in office. Refer to DG / SPECIAL ELECTRICAL SYSTEMS |
Signs
DSF
DOOR SIGNAGE"LIBRARY". Refer to DG / DOOR SIGNS SIGNS GENERALNOTICES Notice "THIS AREA IS UNDER VIDEO SURVEILLANCE", in a conspicuous position. Refer to DG / SIGNS |
Ventilation
OTH
VENTILATION - OTHERRefer to DG / VENTILATION |
Wall
OTH
WALL - OTHERMaximise display potential at high level. Refer to SG / LINING |
Water
N/A
|
Windows
Y